Concrete Rebar Locator Scanner Concrete Protective Layer Tester
Features:
1. The Rebar locator is a portable non-destructive testing instrument, which can be used for the detection of the construction quality of reinforced concrete structures.
2. It can measure the position of steel bars on the concrete surface and detect the
thickness of the protective layer of the steel bars and the diameter of the steel bars.
3. ln addition, the position of magnets and conductors in concrete structures can also be detected, such as cables and plumbing pipes inside walls. The detection before construction can effectively avoid damage to these facilities and reduce accidents.
thickness of the protective layer of the steel bars and the diameter of the steel bars.
3. ln addition, the position of magnets and conductors in concrete structures can also be detected, such as cables and plumbing pipes inside walls. The detection before construction can effectively avoid damage to these facilities and reduce accidents.
Specification
Product model
|
R300
|
|
Applicable range of protective layer thickness(mm)
|
∅6mm~∅50mm
|
|
First range
|
6mm-90mm
|
|
Second range
|
6mm-200mm
|
|
Maximum allowable error of second range protective layer thickness
|
±1(mm)
|
6-80mm
|
±2(mm)
|
81-119mm
|
|
±4(mm)
|
120-200mm
|
|
Applicable scope of diameter estimation
|
∅6mm~∅32mm
|
|
Maximum error of diameter indication
|
±1 specifications
|
|
Section grid
|
Not support
|
|
Storage quantity
|
2000 components*1000 measuring points
|
|
Data transmission mode
|
USB, Wireless clod transport()options
|
|
Power supply mode
|
Lithium battery
|
|
Host parameters
|
Waterproof parameters:IP65
|
|
Screen size: 5 inches
|
||
Resolving power: 320×240
|
||
Volume: 195x140x45mm
|
||
Weight: 0.8kg
|
||
Powder supply
|
Large capacity lithium battery for more than 12 hours
|
|
Working environment requirements
|
Temperature:-10℃~40℃
|
|
Humidity: <90%RH
|
||
Other requirements
|
There is no corrosive gas in the air, No strong electromagnetic interface There should be no major shocks or shocks instruments to
avoid direct sunlight |
|
Packing Specification
|
Material:Engineering plastics Volume: 420x140x335mm Weight: 5.5kg
|
Application
Reviews
There are no reviews yet.